Oil Circuit Breaker Diagram
Oil Circuit Breaker Diagram: In such Oil Circuit Breaker Diagram, some insulating oil (e.g., transformer oil) is used as an arc quenching medium. The contacts are opened under oil and an arc is struck between…
Oil Circuit Breaker Diagram: In such Oil Circuit Breaker Diagram, some insulating oil (e.g., transformer oil) is used as an arc quenching medium. The contacts are opened under oil and an arc is struck between…
Circuit Breakers Definition: A circuit breaker can make or break a circuit either manually or automatically under all conditions viz., no-load, full-load and short-circuit conditions. This characteristic of the Circuit Breakers Definition has made it…
Sequence Networks Unsymmetrical Faults: The analysis of an unsymmetrical fault by symmetrical components method can be conveniently done by drawing sequence networks. A Sequence Networks Unsymmetrical Faults of a particular sequence current in a given…
Analysis of Unsymmetrical Faults: In the Analysis of Unsymmetrical Faults, the following assumptions will be made : The generated e.m.f. system is of positive sequence only. No current flows in the network other than due…
Sequence Impedance of Power System: Each element of power system will offer impedance to different phase sequence components of current which may not be the same. For example, the impedance which any piece of equipment…
Unbalanced Phase Current: The Unbalanced Phase Current in a 3-phase system can be expressed in terms of symmetrical components as under : Fig. 18.6 shows the vector representation of symmetrical components. It is usually profitable…
Unsymmetrical Faults on Three Power System: Those faults on the power system which give rise to unsymmetrical fault currents (i.e. unequal fault currents in the lines with unequal phase displacement) are known as Unsymmetrical Faults…
Location of Reactors in Power System: Short circuit current limiting Location of Reactors in Power System may be connected in series with each generator in series with each feeder and in bus-bars. No definite statement…
Short Circuit kVA: Although the potential at the point of fault is zero, it is a normal practice to express the short-circuit current in terms of Short Circuit kVA based on the normal system voltage…
Percentage Reactance in Power System: The Percentage Reactance in Power System of generators, transformers, reactors etc. is usually expressed in percentage reactance to permit rapid short circuit calculations. The percentage reactance of a circuit is…